Chapter 2 Getting Started
Resetting System Defaults
Quantum A-Series Tape Drives User’s Guide 7
Figure 2 Certificate of Security
Resetting System Defaults
As there is no access to the A-Series tape drive other than the Ethernet
port, a mechanism has been implemented to reset the settings to their
default values. This is useful if an end user loses the IP address of the
A-Series tape drive. The settings can all be set up through the Web
manager (i.e. IP settings, root password, ...).
To have the settings set back to their default values:
1 Switch off your tape drive.
2 Disconnect the network cable from the drive.
3 Repeat the following procedure three times:
a Insert a write protected cartridge into the drive.
b Switch on the tape drive.
c After approximately one minute, the cartridge will be ejected.
d Switch off the drive.