34 The SAN Management Interface
When a SCSI channel is selected, the lower part of the data panel display presents the following
information:
When a Fibre Channel is selected, the lower part of the data panel display presents the following
information:
Serial Baud Rate Speed of the HyperTerminal connection
Health Check Level Level to which Health Check is set, 0-4
Health Check Interval Interval between Health Checks, in minutes
Receive Event Traps Status--either Enabled or Disabled
Ethernet Type 10-base T or 100-base T
UDP Port User Datagram Protocol port where SNMP traps are
received
VPS Enabled
SFM Enabled
Yes (enabled) or No (disabled)
VPM Enabled Yes (enabled) or No (disabled)
Data Mover Module Enabled Yes (enabled) or No (disabled)
Channel Type Low Voltage or High Voltage, Single-Ended or
Differential
Channel Mode Target or Initiator
Host ID (if channel in initiator mode) SCSI Bus Channel ID
Termination Status--either Enabled or Disabled
Max Width Bus width, in bits
Max Speed
Bus speed in megahertz
Status Status--either Operational or Offline
Max IDs per Bus (if channel in initiator mode) Number of SCSI IDs allowed
Max LUNs per ID (if channel in initiator mode) Number of SCSI LUNs allowed
World Wide Port Name Unique 64-bit identifier assigned to this port
World Wide Node Name Unique 64-bit identifier assigned by the manufacturer
Serial Number Number assigned to the FC connector during
manufacturing
Media Short Wave or Long Wave, Dual or Single PMC or GBIC
type
Firmware Revision FC controller firmware version
Port Type Point-to-Point (N_Port), fabric loop (NL_Port),
Fabric_Attached (N_Port), or none
Port Mode Public or Private, Initiator or Target