Quantum Scalar i40 Uživatelská příručka Strana 125

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 340
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 124
Chapter 4: Configuring the Library
Configuring System Settings
Quantum Scalar i40 and Scalar i80 User’s Guide 97
Operator Panel
1 Select Setup > Account Settings > Session Timeout.
The current timeout setting is highlighted.
2 Use the Up and Down buttons to select the desired timeout.
3 Press Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 106).
Configuring System Settings
You can enable/disable the following system settings on the operator
panel:
Unload Assist
Logical Serial Number Addressing
Manual Cartridge Assignment
SNMP
SMI-S
Power Save
Unload Assist When Unload Assist is enabled, the library will unload tape drives when
a move command from the tape drive is received. When Unload Assist is
disabled, the tape drive must be unloaded prior to a move command, or
the move command will fail. This setting is enabled by default.
Operator Panel
1 Select Setup > System Settings > Unload Assist.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.