CHAPTER 4: Thermal Specifications SDLT 220 and SDLT 320 Design & Integration Guide
4-2 March 2004 81-81148-01
If a SCSI command is aborted as a result of the over-temperature condition,
the drive returns status of: Hardware Error, Warning — Specified Temperature
Exceeded (04h, 0Bh, 01h).
4.2 Air Flow Measurements
Air flow is measured in the location shown in Figure 4-1. At the specified location,
the air flow needs to be at least 125 LFM (linear feet per minute). Alternatively
stated, the air flow needs to be at least 7.2 CFM (cubic feet per minute) for tape
drives outfitted with library bezels.
Figure 4-1. Library Bezel—Where to Measure Air Flow
Measure Air
Flow Inside
the Gray Area