Quantum DLT 4000 Manuál Strana 136

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 300
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 135
SCSI Commands
5-36 Quantum DLT 4000 Tape Drive
LOG SELECT Command (4Ch) (continued)
Bit
Byte
7 6 5 4 3 2 1 0
0 -1
(MSB)
Parameter Code
(LSB)
2 DU DS TSD ETC TMC Rsvd LP
3 Parameter Length
4 - 7
(MSB)
Parameter Value
(LSB)
NOTE: Byte 2 is also referred to the Parameter Control Byte.
Figure 5–14 LOG SELECT Log Parameters Format
Table 5–18 LOG SELECT Log Parameters Field Descriptions
Field Name Description
Parameter Code Parameter Codes supported for the READ/WRITE error counter pages are as
follows:
Parameter Code -Descriptions
00h - Errors corrected with substantial delays
01h - Errors corrected with possible delays
02h - Total rewrites or rereads
03h - Total errors corrected
04h - Total times correction algorithm processed
05h - Total bytes processed
06h - Total uncorrected errors
8000h - Vendor Unique
Zobrazit stránku 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 299 300

Komentáře k této Příručce

Žádné komentáře