Quantum Scalar 100 Uživatelská příručka Strana 47

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 46
SNC 6101 User’s Guide 43
Post-Repair Checklist
To ensure a successful SNC 6101 installation, it is important that the items in this checklist be verified after
you have completed the replacement process.
Table 5 Post Replacement Checklist
Step Actions Comments and References
1
Install the replacement SNC
6101 in the Scalar 100.
Refer to Replacing the SNC 6101 on page 37.
2
Ensure that the FC hosts are
turned off. If not, disconnect the
FC cables now.
If you cannot turn off the FC hosts you must
disconnect the FC hosts before turning ON the
SNC 6101. This precaution ensures that FC hosts
cannot perform any I/O to the SCSI target devices
prior to restoring the SNC 6101 configuration.
3
Cable a service terminal to the
service port of the SNC 6101.
Refer to To cable the service port to your laptop/
desktop computer on page 21 and To configure
HyperTerminal for operation as a service terminal
on page 21.
4
Turn on the Scalar 100. None.
5
Wait for the SNC 6101 to finish
booting.
Within one minute, the Ready LED should start
flashing once per second and the “Done executing
startup script” message should be displayed on the
service terminal.
6
From the service terminal, enter
the scsiShow command.
Refer to the SNC Firmware 4 User’s Guide.
Verify that all attached SCSI devices appear in the
output report. Refer to To configure the SNC 6101
on page 22 for a sample report.
7
Modify the WWN for a
replacement SNC 6101 only if it
is critical that the replacement
have the same WWN as the
replaced SNC 6101.
Refer to Changing the WWN
on page 37.
8
Configure network parameters
for the SNC 6101.
Refer to To configure the SNC 6101 on page 22 for
parameter setup procedures.
9
Perform the following:
If more current firmware is
available, update the firmware.
Load the configuration file you
saved in Step 1
of Removing
and Replacing the SNC 6101
on page 36.
Restart the SNC 6101.
For firmware update procedures, refer to To
upgrade SNC 6101 Firmware on page 25.
Refer to the SNC Firmware 4 User’s Guide for
information on saving a configuration file.
10
Reconnect the FC cables
removed in step 2, or, if you
turned OFF any FC hosts, turn
them back ON.
If FC1 and/or FC2 Connection Status LEDs for the
attached Hosts are not ON, you may need to
change the polarity of the FC cables.