Quantum MC300 Uživatelská příručka Strana 109

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 222
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 108
Chapter 6 Updating Drive Firmware
Updating the Drive Firmware from Tape
ATL M-Series User’s Guide 91
Updating the Drive Firmware from Tape 6
To update the drive firmware from tape:
1 Insert the drive firmware cartridge into the library and move it to the
desired storage element (see Importing and Exporting Cartridges
on
page 29).
2 Access the Service Drive screen (see Accessing the Service Drive
Screen).
3 Press
Update.
The GUI displays the
Select Firmware Cartridge screen (see figure 58).
A flashing arrow indicates the currently selected source element.
Figure 58 Select
Firmware Cartridge
Screen
4 If the library is an M1500 in a multiple library stack or an M2500,
press the
Level button to select the level where the drive firmware
cartridge is located.
5 Press the
Up and Down buttons to select the source element that
contains the drive firmware cartridge.
6 When the flashing arrow is next to the source element that contains
the drive firmware cartridge, press
Select.
The GUI displays the
Select Tape Drive screen (see figure 59). A
flashing arrow indicates the currently selected drive.
Zobrazit stránku 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 221 222

Komentáře k této Příručce

Žádné komentáře