Chapter 9: Troubleshooting
Running the IVT Diagnostic Subtests Individually – Robotics, Tape Drive, and Magazine Tests
Quantum Scalar i40 and Scalar i80 User’s Guide 257
changes to “Running.” Once a test completes, its progress changes
to either “Passed” or “Failed.”
You can stop the IVT by pressing the Stop button. The progress of
the currently running test changes to “Stopping.” Once stopped,
the current test and all other scheduled tests display “Stopped.”
Running IVT logs all users off of the Web client.
You can only perform the IVT from the operator panel.
Operator Panel
1 Install a scratch tape in the top I/E station slot.
2 If manual cartridge assignment is enabled, assign the scratch tape
to the System partition.
3 Select Tools > IVT.
4 Press Yes to start the test.
Running the IVT Diagnostic Subtests Individually –
Robotics, Tape Drive, and Magazine Tests
If you do not need to run the full IVT, you can run the robotics, tape
drive, or magazine test separately to check an individual component.
You should do this when you remove, replace, or service a component
that does not require you to remove the library into or out of a rack or
desktop kit.
Details about running the diagnostic subtests is the same as for the full
IVT (see
Running the Installation and Verification Test (IVT) on page 255)
with the following exceptions:
For the Tape Drive and Magazine diagnostics, you will choose just
one device on which to run the diagnostic, rather than all. The tape
drive test only tests the selected tape drive. The magazine test tests
all the slots in the selected magazine.
Zobrazit stránku 282