JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
10-17
WHAT THE LIBRARY RETURNS
The handling of the element address reserved for the cleaning cartridge is
unchanged on all LOG SELECT and LOG SENSE log pages.
When a MODE SELECT command changes the values for both the FixEnbl and
the Auto bits (either both turned on or both turned off), the library returns NOT
READY TO READY Unit Attention (ASC/ASCQ of 28h/00h) message after the
successful completion of the command.
Cleaning Cartridge Storage Element – Byte 3
This field indicates the element address of the storage element that is reserved
for a cleaning cartridge. This field is only valid when the FixEnbl bit is 1.
10.3.8 OPERATING MODE PAGE (PAGE CODE 26h)
The Operating Mode page indicates the current operating mode for the
library. For more information about operating modes, refer to the Magnum 224,
StorageLibrary T24, or StorageLoader 2U LTO Library Product Manual or the
Magnum 448 LTO Library Product Manual.
PS (Page Savable) – Byte 00, Bit 7
The value returned for this field is 0, which indicates that the library cannot
save this page to nonvolatile memory.
Page Code – Byte 00, Bits 5 through 0
This field identifies the Clean Configuration page. The value of this field must
be 26h.
Parameter Length – Byte 01
This field indicates the length, in bytes, of the Operating Mode page. The valid
value for this field is 02h (2), which indicates that 2 bytes of data follow this
byte.
Bit
Byte
7 6 5 4 3 2 1 0
00 PS RSVD Page Code (26h)
01 Page Length (02h)
02 Reserved OperMode
03 Reserved