A-20
SCSI REFERENCE 1014826
CHAPTER A—ERROR CODES
A.2.2 ERROR CODES IN ASCENDING FSC ORDER
Ta b l e A - 4 lists the same information as Ta b l e A - 3 , but it is sorted in ascending
FSC order.
Table A-4 REQUEST SENSE error information (FSC, ASC, ASCQ, and SK
FSC
ASC
(byte 12)
ASCQ
(byte 13)
Sense
Key
Cause ERP SCSI Error Message and Description
— 83h 00h T, L 14, 16,
12
Bad label. Questionable.The bar code
label is questionable. Issue an INITIALIZE
ELEMENT STATUS (07h or E7h) command
to reread the label.
— 83h 01h T, L 14, 16,
12
Bad Label. Unreadable. Cannot read bar
code label.
— 83h 03h T, L 14, 16,
12
Bad Label. Full Question. Label and full
status questionable. The library was
powered on or the cartridge access port
door was opened. The cartridge inventory
may have been violated. Issue an
INITIALIZE ELEMENT STATUS (07h or
E7h) command to reestablish the cartridge
inventory.
— 83h 09h O, T 10, 16,
12
Bad Label. No Label. The bar code
scanner could not read the bar code label
because there was no label on the
cartridge or the label was unreadable.
— 83h 0Ah L 12 Bad Label. Hardware Error. The library is
unable to read the bar code label due to a
bar code reader hardware error.
00h 00h 00h 0h I 10 No error.
00h 28h 00h 6h I 10, 11 Not Ready to Ready. Door closed. The
library’s door was opened and then
closed.
00h 28h 01h 06h I 10, 11 Not Ready to Ready. I/E Port accessed.
00h 29h 00h 6h I 10, 11 Power on or reset. A power-on, SCSI bus
reset, or Target Reset message occurred.
00h 2Ah 01h 6h I 10, 11 Mode parameters changed. Mode
parameters have been changed. Issue a
MODE SENSE (1Ah) command to
determine what the new mode
parameters are.