JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
9-3
WHAT YOU SEND TO THE LIBRARY
For example, if you want to transfer the LCD Mode page, set the parameter list
length to 40 bytes (28h):
If you want to transfer all of the available mode pages, set the parameter list
length to 70 (46h):
9.2.1 PARAMETER LIST HEADER
If you send one or more parameter pages with the MODE SELECT command,
you must send a Parameter List Header. Do not send the Parameter List
Header if you are not sending any parameter pages.
All fields of the Parameter List Header are reserved. You must specify a value
of 0 for each field.
9.2.2 ELEMENT ADDRESS ASSIGNMENT PAGE (PAGE CODE 1Dh)
This section describes the fields for the Element Address Assignment page and
the values you can specify for these fields. Refer to “Elements and Element
Addresses on page 2-2 and to Assigning Element Addresses” on page 9-4 for
an explanation of element addresses.
4 bytes (Parameter List Header length)
+ 36 bytes (LCD Mode page length)
40 bytes
4 bytes (Parameter List Header length)
20 bytes (Element Address Assignment Page)
6 bytes (Unique Properties Page)
36 bytes (LCD Mode Page)
+ 4 bytes (Cleaning Configuration Page)
70 bytes
Bit
Byte
7 6 5 4 3 2 1 0
00
Reserved
01
02
03