24-2
SCSI REFERENCE 1014826
CHAPTER 24—TEST UNIT READY (00h)
Reservation Conflict
The library returns Reservation Conflict status when it is reserved by a
different initiator. See Chapter 20 for more information about the RESERVE
command.
Check Condition
The library returns Check Condition status for the following reasons:
The command is issued to an invalid LUN.
A Unit Attention condition is pending for the initiator.
The library has experienced an unrecoverable hardware error.
The library is not ready because a magazine is removed.
A reserved bit is set to 1 in the CDB.
A parameter in the CDB or parameter list is invalid (see Table 24-1 for sense
data).
Table 24-1 Invalid parameters in the TEST UNIT READY CDB and parameter list
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 24h 00h 1 1 1
A reserved bit is set in the CDB. The
pointers point to the bit in error.