SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-153
4.14 READ Command (08h)
The READ command transfers one or more data blocks or bytes to the initiator starting with the next
block on the tape.
Figure 4-83. READ Command Descriptor Block — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation Code (08h)
1 Reserved SILI Fixed
2 – 4
(MSB)
Transfer Length
(LSB)
5 Control
Table 4-88. READ Command Descriptor Block — Field Descriptions
Field
Name Description
SILI Suppress Incorrect Length Indicator. If the SILI bit is set to 1 and the Fixed bit is
set to 1, the drive terminates the command with CHECK CONDITION status,
Sense Key set to ILLEGAL REQUEST, and Additional Sense Code set to
INVALID FIELD IN CDB.
If the SILI bit is set to 0 and the actual block length is different than the specified
transfer length, the drive returns CHECK CONDITION status. Within the Sense
Data, the Incorrect Length Indicator (ILI) bit and Valid bit are set to 1. The Sense
Key field is set to NO SENSE. The information bytes are set to the difference
(residue) between the requested transfer length and the actual block length, or, in
Fixed Block mode, the difference (residue) between the requested number of
blocks and the actual number of blocks read. No more than Transfer Length
blocks are transferred to the initiator and the drive logically positions the tape
after the block (EOM side).