SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-47
4.8.4 LAST n ERROR EVENTS Log Page (07h)
This page returns one parameter at a time that contains the ASCII text for the specified event log. The
Parameter Number field in the CDB specifies the log event to return. The log events in EEPROM are
numbered from 0 to 255, after which the number wraps back to 0. A maximum of 32 events are stored
at a given time. The log event returned is the first one whose parameter code is equal to or greater than
the parameter number specified in the CDB.
Figure 4-21. Last n Error Events LOG SENSE Page — Header Format
Bit
Byte
7 6 5 4 3 2 1 0
0 Page Code (07h)
1 Reserved
2 – 3
(MSB)
Page Length
(LSB)