LOG SENSE Command (4Dh) SDLT 600 SCSI Interface Guide
4-50 January 2005 81-81200-02 REV A01
Table 4-28. Sequential Access Device LOG SENSE Page Parameters — Field Descriptions
Field Name Description
Parameter Code Parameter codes supported for the Sequential Access Device Page are as follows:
Code Description
0000h Host Write Byte Count. This is the number of data bytes received
from application clients during WRITE command operations.
0001h Tape Write Byte Count. The number of data bytes written to the
media during WRITE command operations, not counting ECC and
formatting overhead.
0002h Tape Read Byte Count. The number of data bytes read from the
media during READ command operations, not counting ECC and
formatting overhead.
0003h Host Read Byte Count. The number of data bytes transferred to the
initiator(s) during READ command operations.
DU Disable Update. Always set to 0.
DS Disable Save. Not supported. Always set to 1.
TSD Target Save Disable. Not supported. Always set to 1.
ETC Enable Threshold Comparison. Threshold checking is not supported on this page.
Always set to 0.
TMC Threshold Met Criteria. Ignored. Always set to 0.
LP List Parameter. The drive treats the parameter codes as data counters. Always set
to 1.
Parameter
Length
Specifies the number of bytes in the parameter value. All parameters are 8 bytes in
length.
Parameter Value Indicates the actual value of this log parameter.