LOG SENSE Command (4Dh) SDLT 600 SCSI Interface Guide
4-52 January 2005 81-81200-02 REV A01
Table 4-30. Temperature LOG SENSE Parameters — Field Descriptions
Field Name Description
Parameter Code Parameter codes supported for the Temperature page are as follows:
Code Description
0000h Current operating temperature (degrees Celsius).
0001h Reference temperature (degrees Celsius). This is the maximum
reported sensor temperature at which the tape drive is capable of
operating continuously without experiencing degradation beyond
the limits, specified in the Product Manual for this product.
DU Disable Update. Always set to 0.
DS Disable Save. Not supported. Always set to 1.
TSD Target Save Disable. Not supported. Always set to 0.
ETC Enable Threshold Comparison. Threshold checking is not supported on this page.
Always set to 0.
TMC Threshold Met Criteria. Ignored. Always set to 0.
LBIN List Binary. Always set to 1.
LP List Parameter. The drive treats the parameter codes as data counters. Always set
to 1.
Parameter
Length
Specifies the number of bytes in the parameter value. All parameters are 2 bytes in
length.
Parameter Value Indicates the actual value of this log parameter.