Overview 4-3
22 June 2004
4-
Overview
This chapter contains performance, environmental, electrical,
and physical specification information for the Scalar 1000
library. The information is organized as follows:
Performance Specifications on page 4-3
Environmental Specifications on page 4-3
Electrical Specifications on page 4-4
Physical Specifications on page 4-5
Foot Pad Positions on page 4-6
Barcode Requirements on page 4-7
Performance Specifications
The Scalar 1000 has peak actions per hour of 350 exchanges
and peak time to mount media of 6 seconds.
Environmental Specifications
Table 4-2 lists the key environmental information for the
Scalar 1000 library. Specifications do not include drives.
Table 4-1 Performance Specifications
Avg Actions
per Hour
Peak Actions
per Hour
Avg Time to
Mount Media
Max Time to
Mount Media
290 350 5 Seconds 6 Seconds
Table 4-2 Environmental Specifications
Temperature Humidity Altitude
Maximum BTU/Heat
Dissipation
Operating:
60° - 90° F (16° - 32° C)
Recommended:
70° - 75° F (21° - 24° C)
Non-condensing
Operating:
15 - 75%
Recommended:
45 - 65%
No Limit 0.44 kwh
1502 BTU
Zobrazit stránku 38