Troubleshooting and Help 12-91
Scalar 100
60 xx
Cannot complete the Lock/Unlock Mailbox commands.
Run Lock Diagnostics from the Operator Panel to see if there is any mechanical
bindings. Refer to Locking/Unlocking the Mailbox on page 8-63
.
Contact ATAC.
70 xx
Failures detected in the Picker Assembly Grip Finger Open operation.
Run Grip finger diagnostics. Refer to Exercising the Picker Fingers on page
9-67.
Contact ATAC.
71 xx
Failures detected in the Picker Assembly Grip Finger Close operation.
Run Grip finger diagnostics. Refer to Exercising the Picker Fingers on page
9-67.
Contact ATAC.
72 xx
A Get command was issued but the sensor indicated that a cartridge is
already present in the Picker Assembly.
Look into the Picker Assembly and see if a cartridge is present. If a cartridge is
found in the picker, recover the cartridge and place it in any empty slot, close
the door and retry the failing operation.
73 xx
Failures detected in the Picker Assembly Finger Open/Close operations.
Contact ATAC.
74 00
A Get command was issued but the sensor indicated that the source
location is empty.
This error can be caused by a cartridge that is not fully inserted in the storage
slot above the failing slot. If this condition exists, push the cartridge into its slot
and close the library door.
Contact ATAC.
77 xx
Failures detected in the Picker Assembly during a Retract operation.
Contact ATAC.
78 xx
A Put command was issued but the sensor indicated that the cartridge is
not present in the Picker Assembly.
Contact ATAC.