Getting Information 6-41
Scalar 100
Getting Sensor Information
Use Sensors to view library sensor status. This option displays the real time status of the sensors
in the library.
Path: Main menu > More > Service > Library > Diags > Sensors
To view sensor information
From the Main menu, select Service and then select Library. Select Diags and then
Sensors.
The Sensors dialog is displayed, with the following information:
NOTE:
For information on using Lock/Unlock to lock or unlock the Mailbox, see
Locking/Unlocking the Mailbox on page 8-63
.
Field Value Description
PwrFan 0 The power supply fan is not running.
PwrFan 1 The power supply fan is running.
PwrSply 0 Additional power supply is not installed.
PwrSply 1 Additional power supply is installed.
DrvRmvd 0 Drive has not been removed.
DrvRmvd 1 Drive has been removed.
GrpThrm 0 Gripper thermometer not installed.
GrpThrm 1 Gripper thermometer installed.
GrpClsd 0 Gripper is open.
GrpClsd 1 Gripper is closed.
IE Lock 0 Mailbox is unlocked.
IE Lock 1 Mailbox is locked.
IE Open 0 Mailbox is closed.
IE Open 1 Mailbox is open.
IE Closed 0 Mailbox is open.
IE Closed 1 Mailbox is closed.
DoorOpn 0 Front door is closed.
DoorOpn 1 Front door is open.