Quantum Scalar 100 Uživatelská příručka Strana 80

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 126
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 79
9-70 6-00667-01 Rev B
Scalar 100
Moving the Picker in Increments
Use Step to manipulate the vertical and rotary axes of the picker in incremental steps.
Path: Main menu > More > Service > Library > Diags > Picker > Step
To move the picker
1. From the Main menu, select More and then select Service. Select Library and then select
Diags. Select Picker and then select Step.
2. A dialog is displayed warning that only qualified personnel should operate this feature. Select
OK.
3. Using Up, Down, and Next, complete the following fields. The picker moves as you press these
buttons.
Pivot axis — specifies the number degrees the picker will rotate. Possible values are 0 to
275 degrees.
Vert. axis — specifies how many millimeters the picker will be extended during this
exercise. Possible values are 0 to the maximum height for your library.
Step amount — specifies how many tenths of millimeters the picker should step. Possible
values are 1 to 100.
Sending the Picker to the Home Position
Use Home to send the vertical and rotary axes to their home positions.
Path: Main menu > More > Service > Library > Diags > Picker > Home
To move the picker
1. From the Main menu, select More and then select Service. Select Library and then select
Diags. Select Picker and then select Home.
2. Select OK.
Exercising the Library
Use Exercise to access library exercises. You can run a demonstration, self test, or teach
operation. These exercises are helpful when troubleshooting and when testing new configurations.
NOTE:
This is an advanced diagnostic tool that is not intended for use during normal
operation.
Zobrazit stránku 79