4-56 Menus and Commands
6-00058-05 Rev A
Eject Dialog
Path: Main Menu Commands Insert/Eject Eject
Use the Eject Dialog to remove cartridges without opening the
service or access doors, or without host intervention. The final
destination is a slot in the Insert/Eject station. See Figure 4-73.
If your library is host partitioned, do not use the operator
panel to move a cartridge. The library does not know the
partition limits and could move a cartridge outside of the
partitioned area, making that cartridge inaccessible to the
host.
Figure 4-73 Eject Dialog
Parameters Description
Coord The first field indicates the
type of cell (I for I/E Station, D
for Drive, S for Storage cell)
The second field indicates the
rack number (01–16)
The third field indicates the
storage cell section (1–5)
The fourth field indicates the
column of the section (A–P)
The fifth field indicates the
row of the column (01–15)
Index Indicates the number
corresponding with the
coordinate parameter
Accept Y to accept
N to reject
If Y is selected, the Eject Screen appears. See
Figure 4-74. Otherwise, the changed actions continue
to display but no action is taken.
Caution
Enter SOURCE
Coord: S< 01 1 A 01
Index :ST 00001
Accept: N