5-8 Processing Media
6-00058-05 Rev A
Step 2 Select Status Change.
The Set Status Dialog appears. See Figure 5-2.
Figure 5-2 Set Status Dialog
Step 3 Select the TM to change.
Step 4 Change the Mode field to USER.
The State automatically changes to NOT READY.
Step 5 Change Accept to Y.
TOWER MODE CHANGE appears. See Figure 5-3.
Figure 5-3 Tower Mode Change
Step 6 Change Continue to Y.
The tower changes the State to NOT READY.
Figure 5-4 Set Status Dialog
Step 7 Open the TM service door.
Step 8 Grasp the tower firmly at the top of the columns or
where the racks are joined (where the sheet metal is
visible) to rotate to the column that you want to
load.
Tower : 01 LTO <
Mode : LIBRARY
State : READY
Accept: N
TOWER MODE CHANGE
This selection will
prevent host access.
Continue: N <
Tower : 01 LTO <
Mode : USER
State : NOT READY
Accept: N