6-18 Error Messages
6-00058-05 Rev A
21 00 00 NVRAM failures.
Action 1
Power Off and On the Scalar 10K library to recover from the error. Refer to
Shutting Down the Scalar 10K on page 3-8 and Starting the Scalar 10K on page
3-7. Wait at least one minute between powering Off and On the library.
Action 2
If the problem is not corrected or persists, contact GCH. For GCH contact
information, refer to Getting More Information or Help on page 1-8.
22 00 00 Fail to communicate with the operator panel.
Action 1
Contact GCH. For GCH contact information, refer to Getting More Information
or Help on page 1-8.
23 00 00 An unexpected interrupt is received.
Action 1
Contact GCH. For GCH contact information, refer to Getting More Information
or Help on page 1-8.
30 00 00 A fatal error is detected in SCSI port 1.
Action 1
Verify that the SCSI bus connected to Library Port 1 is properly terminated
and powered.
Action 2
Verify that the SCSI ID is unique for the SCSI cable.
Action 3
Verify that the Library SCSI Port 1 is properly configured by using the
operator panel (Main Menu Setup Library SCSI Ports).
Action 4
If the problem is not corrected or persists, contact GCH. For GCH contact
information, refer to Getting More Information or Help on page 1-8.
Table 6-2 Service Action Codes (Continued)
Reported
SAC
Perform these actions
Zobrazit stránku 291