Scalar 100 User’s Guide 101
46 xx
The barcode scanner detected a cartridge when one was not expected.
This occurs because the magazine’s fiducial label was not scanned by the
library. Therefore, the library does not recognize the magazine as being
installed in the column.
This error can be caused by a dirty barcode scanner (dust or fingerprints). Verify
that the barcode scanner is clean.
Check for a dirty, damaged, missing or wrong fiducial label on the magazine
containing the cartridge in question.
Contact ATAC if the barcode scanner is dusty or has finger prints.
60 xx
Cannot complete the lock/unlock mailbox commands.
Run lock diagnostics from the operator panel to see if there is any mechanical
bindings. Refer to
Locking/Unlocking the Mailbox on page 73.
Contact ATAC.
70 xx
Failures detected in the picker assembly grip finger open operation.
Run grip finger diagnostics. Refer to Exercising the Picker Fingers on page 77.
Contact ATAC.
71 xx
Failures detected in the picker assembly grip finger close operation.
Run grip finger diagnostics. Refer to Exercising the Picker Fingers on page 77.
Contact ATAC.
72 xx
A get command was issued but the sensor indicated that a cartridge is
already present in the picker assembly.
Look into the picker assembly and see if a cartridge is present. If a cartridge is
found in the picker, recover the cartridge and place it in any empty slot, close
the door and retry the failing operation.
73 xx
Failures detected in the picker assembly grip finger open/close
operations.
Contact ATAC.
74 xx
A get command was issued but the sensor indicated that the source
location is empty.
This error can be caused by a cartridge that is not fully inserted in the storage
slot above the failing slot. If this condition exists, push the cartridge into its slot
and close the library door.
Contact ATAC.
77 xx
Failures detected in the picker assembly during a retract operation.
Contact ATAC.
Table 8 Service Action Code Descriptions
Reported
SAC
Error and Solution