Scalar 100 User’s Guide 105
Operator Intervention Messages
When operator intervention is required, operator intervention messages display on the operator panel.
Operator intervention messages are up to four lines in length. The third and/or fourth lines may contain
variable information specific to the message. For SAC indications, refer to
Service Action Codes on page
97.
E8 xx
During a put cartridge after a successful get command, the picker
assembly detected that the cartridge is no longer present in the grip
fingers. Locate the missing cartridge.
If a cartridge is found, recover the cartridge, re-inventory the library and retry
the operation.
Contact ATAC.
EB xx
An invalid library configuration was detected: the AIT drive modules are
not installed in the allowable configurations.
Check to make sure that AIT tape drive modules are installed as specified in the
procedure
Installing/Removing Drives on page 27. Drive module 1 must be
installed starting at slot 2 of the drive column and additional modules occupying
drive slots (3 to 5) moving upward with no gap between modules.
FB xx
Annual reminder.
This is an annual reminder to inspect the library for dust accumulation on the
front door air vents. Blocked vents could affect the airflow required for proper
cooling drives and electronics.
After inspecting the air vents for dust accumulation, the SAC FB can be cleared
for another year by choosing one of the following options on the operator panel:
select More > Service > Start > Normal > Next or OK > Cancel or OK to
continue normal operation.
Table 9 Operator Intervention Messages
Message Lines Variables
Alert not found.
Press OK.
None
-=>ERROR!<=-
Initialization Error
Code: 0x%Y
%Y = 4 digit error modifier
-=>PERM ERROR!<=-
CALL FOR SERVICE
SAC :%X
Code:0x%Y
%X = 2 digit hex
%Y = 4 digit error modifier
Table 8 Service Action Code Descriptions