Scalar 100 User’s Guide 69
Configuring Additional Library Options
Use Config to configure additional library characteristics. These characteristics include:
• Choosing whether the operator panel LCD has a backlight.
• Choosing whether or not to enable key strokes sounds when pressing library buttons.
• Setting whether the library scans all barcodes when the library is booted up. Note that the library
must either scan or touch all media cartridges when booted.
• Setting whether the library touches all media cartridges when booted. Note that the library must
either scan or touch all media cartridges when booted.
• Setting the mailbox for import/export commands or as additional storage.
Path: Main Menu > More > Setup > Utils > Config
1 From the main menu, select More. Select Setup and then select Utils. Select Config.
The Config dialog box displays.
2 Using Yes/No, Next, and Change, set the following fields:
• Backlight on — Sets the backlight on or off. Possible values are Yes or No.
• Audio on — Determines whether key stroke sounds are made when a button is pressed. Possible
values are Yes and No.
• Scan on Init — Indicates whether the library will scan all tape cartridge barcodes when the library
is booted up. Note that either Scan on Init or Touch on Init must be enabled. Possible values are
Yes or No.
• Touch on Init — Indicates whether the library picker will touch all tape cartridges when the library
is booted up. Note that either Scan on Init or Touch on Init must be enabled. Possible values are
Yes or No.
• Mailbox — Determines whether the mailbox will be used to import and export tape cartridges or if
the mailbox will be used as storage slots.
• Imprt/Exprt — Indicates the mailbox is for importing or exporting tape cartridges.
• Storage — Indicates the mailbox is for storage.
3 Select OK.